| Versatility- A single unit for push or pull applications
| -24VDC high speed operation |
| -25 lbs force at min stroke, 11 lbs at max stroke, 27 lbs holding (without return spring) |
|
-14 lbs force at min stroke, 7 lbs at max stroke, 15 lbs holding (with return spring) |
| -Continuous duty rated |
| -29 amps inrush, .5 amps holding current @ 24VDC |
| -Will operate at any stroke less than maximum (1") |
|
-Unit comes complete with return spring, rubber boot, threaded shaft and nut |
|
-24 oz shipping weight |
Application notes:
|
-Energize Coil should not be energized for longer than 15 seconds to avoid coil damage |
|
-Precautions should be taken to avoid overheating Energize Coil via proper wiring/switching setup and/or use of SD85 Energize/Hold control relay |
|
-Allow 15 minutes cooling time between activations of the Energize Coil (less for shorter energize coil cycles) |
|
-Energize Coil must fully seat the plunger to allow Hold Coil to function properly |
| -Do not mount with boot down (unit is recommended for horizontal application only) |
|
-Do not apply grease or lubrication to parts |
| -Use minimum 10 AWG wire size as noted in wiring diagram and keep wire lengths to a minimum |
| -Caution: The solenoid housing is hot to the touch. A temperature rise to 185°F (85°C) is permissible |
|